Home ProductsIntrinsic Safety Barrier

Eaton MTL7764AC Zener Safety Barrier 12V 1000Ω ATEX Approved for Hazardous Areas

Certification
China Shenzhen Hengyo Power Technology Co., Limited certification
China Shenzhen Hengyo Power Technology Co., Limited certification
I'm Online Chat Now

Eaton MTL7764AC Zener Safety Barrier 12V 1000Ω ATEX Approved for Hazardous Areas

Eaton MTL7764AC Zener Safety Barrier 12V 1000Ω ATEX Approved for Hazardous Areas
Eaton MTL7764AC Zener Safety Barrier 12V 1000Ω ATEX Approved for Hazardous Areas

Large Image :  Eaton MTL7764AC Zener Safety Barrier 12V 1000Ω ATEX Approved for Hazardous Areas

Product Details:
Place of Origin: England
Brand Name: Eaton
Certification: CE
Model Number: MTL7764AC
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: negotiable
Packaging Details: original package
Delivery Time: In stock
Payment Terms: T/T,Western Union
Supply Ability: 500pcs/month
Contact Now Chat Now

Eaton MTL7764AC Zener Safety Barrier 12V 1000Ω ATEX Approved for Hazardous Areas

Description
Condition: MTL Original Brand New Warranty: One Year
Application: Oil Gas Chemical Industry Shipping Way: DHL FedEx
Highlight:

MTL Zener safety barrier isolator

,

intrinsic safety barrier with warranty

,

MTL7764AC Zener barrier isolator

Eaton MTL MTL7764AC Zener Safety Barrier 12V 1000Ω ATEX Approved Hazardous Area
Product Overview

The MTL7764AC is a high-performance shunt-diode safety barrier (Zener barrier) from Eaton's Crouse-Hinds series MTL7700 range, specifically engineered for strain-gauge bridge circuits, load cells, and Wheatstone bridge applications requiring intrinsic safety protection in hazardous areas.

This passive device limits the voltage and current that can reach a hazardous area under fault conditions, preventing ignition of flammable atmospheres. With a rated voltage of 12 V, end-to-end resistance of 1,000 Ω, and maximum current of 12 mA, the MTL7764AC is the ideal solution for protecting sensitive strain-gauge based measurement equipment in Zone 0, 1, and 2 hazardous locations (gas groups IIC, IIB, IIA).

The device features a compact 12 mm width and standard DIN rail mounting for easy integration into existing control cabinets.

Model Number Decoding: MTL7764AC
Code Segment Meaning
MTL MTL Instruments Group (now Eaton)
77 MTL7700 series — Shunt-diode safety barriers
64 Specific barrier configuration for strain-gauge bridges
AC AC/DC compatible — suitable for both AC and DC circuits

The "AC" suffix indicates compatibility with AC circuits, distinguishing it from polarity-sensitive models.

Key Features & Benefits
Strain-Gauge Bridge Optimization: Specifically designed for strain-gauge bridge circuits and load cell applications
12 V Working Voltage: Provides safe voltage limiting for strain-gauge bridge circuits
1,000 Ω End-to-End Resistance: Matches impedance requirements of typical strain-gauge bridge circuits
12 mA Maximum Current: Adequate current handling for strain-gauge bridge excitation
AC/DC Compatibility: Suitable for both AC and DC circuits — no polarity concerns
Ultra-Slim DIN Rail Mounting: Compact 12 mm width saves valuable panel space
High Accuracy Signal Transfer: Minimal signal distortion for sensitive measurements
Multiple International Approvals: ATEX, TIIS, and Factory Mutual certifications
Technical Specifications
General Specifications
Parameter Value
Manufacturer Eaton (Crouse-Hinds series MTL)
Series MTL7700 Range
Product Model MTL7764AC
Alternative Part Number 5710-032-006
Product Type Shunt-Diode Safety Barrier (Zener Barrier)
Electrical Ratings
Parameter Value
Working Voltage (Vwkg) 12 V
Maximum Current 12 mA
End-to-End Resistance 1,000 Ω
Resistance Tolerance ±10 %
Fuse Rating 50 mA
Number of Channels 1 (single-channel)
Polarity AC (non-polarized)
Hazardous Area Specifications
Parameter Value
Gas Groups IIC, IIB, IIA
Zones Zone 0, 1, 2
Safety Description 12 V, 1,000 Ω, 12 mA
Mechanical Specifications
Parameter Value
Width 12 mm
Height 86 mm
Length/Depth 105 mm
Weight 100 g / 0.121 kg
Enclosure Material Polycarbonate
Mounting DIN rail (35 mm)
Terminals Screw terminals
Function Description

The MTL7764AC is a passive shunt-diode safety barrier that operates on the Zener barrier principle. It limits both voltage and current that can be delivered to a hazardous area circuit under fault conditions.

How it works:
  • Voltage limiting: Zener diodes clamp the output voltage to a safe level (12 V) if the safe-area voltage rises above normal operating levels
  • Current limiting: A series resistor (1,000 Ω) limits fault current to a safe value (12 mA)
  • Fusing: Internal 50 mA fuses provide backup protection under severe fault conditions
  • Grounding: The barrier requires a connection to a high-integrity earth ground to function properly
Typical strain-gauge bridge configuration:
  • The MTL7764AC is typically used in conjunction with other MTL barriers for complete strain-gauge bridge protection:
    • MTL7761ac: Provides bridge excitation power (14 V, 230 Ω source)
    • MTL7764ac: Used to sense the bridge supply voltage
    • MTL7766Pac: Provides 12.3 V for 350 Ω bridges with 20 V supply
  • For load cells with resistance between 350 Ω and 800 Ω, the MTL7764AC provides safe excitation and signal conditioning
Load cell application note:
The MTL7764AC is approved by Factory Mutual for use with 1 to 4 load cells in a clear covered polycarbonate junction box. The indicator can have excitation voltage of 10 to 20 V DC and must have remote sense ability. Load cells with Wheatstone bridge circuits are classified as "Non-energy Storing Simple Apparatus" (per ANSI/ISA-RP12.6) requiring no additional approvals when connected to certified intrinsic safety barriers.
Applications

The MTL7764AC is specifically designed for strain-gauge and load cell applications in hazardous area installations:

Industry Application
Oil & Gas Tank level measurement using load cells on storage tanks in Zone 0/1 areas
Chemical Processing Vessel weighing systems, hopper scales, and silo level monitoring
Pharmaceutical Batch weighing systems for solvent handling equipment requiring Ex protection
Mining Conveyor belt weighing systems, bin level monitoring
Food & Beverage Tank weighing for flammable liquid storage (spirits, oils)
Marine & Offshore Cargo tank monitoring, mooring line tension measurement
Typical field devices connected:
  • Strain-gauge bridge sensors (full Wheatstone bridge configuration)
  • Load cells (350 Ω to 800 Ω resistance)
  • Torque sensors
  • Pressure sensors based on strain-gauge technology
  • Weighing systems in hazardous areas
Why Choose the MTL7764AC?
Optimized for Strain-Gauge Bridges
Unlike general-purpose safety barriers, specifically designed for strain-gauge bridge circuits and load cells
AC/DC Flexibility
Non-polarized operation eliminates wiring errors and simplifies installation
Proven MTL7700 Series Reliability
Industry standard for shunt-diode safety barriers for decades
Global Approvals
Certified for use in major industrial markets worldwide
Simple Installation
DIN rail mounting, clearly labeled terminals, and compact design
Load Cell System Compatibility
Factory Mutual approved for use with 1 to 4 load cells
MTL7764AC vs. Related MTL7700 Series Models
Model Working Voltage Current Resistance Polarity Application
MTL7764AC 12 V 12 mA 1,000 Ω AC Strain-gauge bridges, load cells
MTL7760ac 7 V 72 mA 85 Ω AC General purpose AC circuits
MTL7761ac 10 V 93 mA 300 Ω AC AC circuits, general purpose
MTL7761Pac 10 V 93 mA 300 Ω AC Power bus version
MTL7765ac 12 V 93 mA 300 Ω AC AC circuits, higher current
MTL7766ac 14 V 93 mA 300 Ω AC AC circuits, higher voltage
MTL7766Pac 14 V 93 mA 300 Ω AC Power bus version, 12.3 V for 350 Ω bridge
Installation Information
Parameter Detail
Mounting Standard 35 mm DIN rail (EN 60715)
Terminals Screw terminals (accepts up to 2.5 mm² wire)
Grounding Requires high-integrity earth ground connection
Clearance Minimal — 12 mm width enables high-density installation
Operating Position Any orientation
Important Installation Notes:
  • A high-integrity earth ground connection is mandatory for proper Zener barrier operation
  • Do not install in areas where condensation may occur
  • The barrier must be installed in a safe area (non-hazardous location)
  • Maximum cable parameters for IIC gas group apply to field wiring
  • For load cell applications, ensure the indicator has remote sense capability
Compliance & Certifications
Certification Status Details
ATEX Certified BAS01 ATEX 7217 — II (1) GD [Ex ia] IIC
TIIS (Japan) Certified TC16441 (expired July 2024, renewal available)
Factory Mutual (FM) Approved For load cell applications with 1-4 load cells
CSA Certified North American approval
RoHS Compliant Lead-free
CE Compliant EMC Directive
Related Products from MTL7700 Series for Strain-Gauge Applications
Model Function Description
MTL7761ac Excitation Supply 10 V, 300 Ω source for bridge excitation
MTL7764ac Bridge Sense 12 V, 1,000 Ω, 12 mA — senses bridge supply voltage
MTL7766Pac Bridge Power 14 V, 300 Ω — provides 12.3 V for 350 Ω bridge
MTL7761Pac Power Bus Version Same as MTL7761ac with power bus capability
MTL7706+ Single-Channel Barrier 28 V, 93 mA, 300 Ω — general purpose positive polarity
MTL7787+ Dual-Channel Barrier 28 V, 93 mA, 300 Ω — general purpose positive polarity

The MTL7700 series offers a complete range of shunt-diode safety barriers for all intrinsic safety applications.

Overall Rating

5.0
Based on 50 reviews for this supplier

Rating Snapshot

The following is the distribution of all ratings
5 stars
100%
4 stars
0%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

O
Oscar
United States Dec 24.2025
the best seller!
A
ABDULHADI
Saudi Arabia Dec 16.2020
منتج ممتاز
J
Juan
Ecuador Jan 17.2019
all is ok !!
Contact Details
Shenzhen Hengyo Power Technology Co., Limited

Contact Person: Vivian Chan

Tel: +86 13510341645

Send your inquiry directly to us (0 / 3000)