Home ProductsIntrinsic Safety Barrier

Pepperl+Fuchs KFU8-UFC-Ex1.D Frequency Converter, 1-Channel Isolated Barrier 0.001-5000Hz Input, 4-20mA Output, SIL2 In Stock

Certification
China Shenzhen Hengyo Power Technology Co., Limited certification
China Shenzhen Hengyo Power Technology Co., Limited certification
I'm Online Chat Now

Pepperl+Fuchs KFU8-UFC-Ex1.D Frequency Converter, 1-Channel Isolated Barrier 0.001-5000Hz Input, 4-20mA Output, SIL2 In Stock

Pepperl+Fuchs KFU8-UFC-Ex1.D Frequency Converter, 1-Channel Isolated Barrier 0.001-5000Hz Input, 4-20mA Output, SIL2 In Stock
Pepperl+Fuchs KFU8-UFC-Ex1.D Frequency Converter, 1-Channel Isolated Barrier 0.001-5000Hz Input, 4-20mA Output, SIL2 In Stock

Large Image :  Pepperl+Fuchs KFU8-UFC-Ex1.D Frequency Converter, 1-Channel Isolated Barrier 0.001-5000Hz Input, 4-20mA Output, SIL2 In Stock

Product Details:
Place of Origin: Singapore
Brand Name: PEPPERL+FUCHS
Certification: CE
Model Number: KFU8-UFC-Ex1.D
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: negotiable
Packaging Details: original package
Delivery Time: In stock
Payment Terms: T/T,Western Union
Supply Ability: 500pcs/month
Contact Now Chat Now

Pepperl+Fuchs KFU8-UFC-Ex1.D Frequency Converter, 1-Channel Isolated Barrier 0.001-5000Hz Input, 4-20mA Output, SIL2 In Stock

Description
Condition: PEPPERL+FUCHS Original Brand New Application: Used For Intrinsic Safety Applications
Shipping Way: DHL FedEx Warranty: One Year
Highlight:

Pepperl Fuchs safety barrier frequency converter

,

Intrinsic safety barrier with trip values

,

KFU8-UFC-Ex1.D frequency converter

Pepperl+Fuchs KFU8-UFC-Ex1.D Frequency Converter

1-Channel Isolated Barrier with 0.001-5000Hz Input, 4-20mA Output, SIL2 Certified

Product Overview

The Pepperl+Fuchs KFU8-UFC-Ex1.D is a 1-channel isolated barrier frequency converter from the K-System, designed for intrinsic safety applications in hazardous areas. This versatile device converts digital input frequency signals into proportional 0/4-20 mA analog output signals while functioning as both a switch amplifier and trip alarm.

Note: A successor product is available. Please verify stock availability before ordering.
Key Specifications
Parameter Specification
Model KFU8-UFC-Ex1.D
Brand Pepperl+Fuchs
Product Type Frequency Converter / Isolated Barrier (1-channel)
Input Types NAMUR (EN 60947-5-6) or Dry Contact
Input Frequency 0.001 ... 5000 Hz (1 mHz - 5 kHz)
Output I, II Relay (Form C), 250V AC/2A, 40V DC/2A
Output III Electronic/Transistor output, passive, 40V DC/50mA
Output IV Analog output, 0/4-20 mA, load ≤ 650 Ω
Supply Voltage 20-90V DC / 48-253V AC (50-60 Hz)
Safety Rating SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511
Accuracy 0.1% of measured value
Ambient Temperature -20°C ~ 60°C (-4°F ~ 140°F)
Mounting 35mm DIN rail acc. to EN 60715
Dimensions (WxHxD) 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 in)
Certifications ATEX, IECEx, FM, SIL2, CE, UKCA
Key Features
Intrinsic Safety & Hazardous Area Protection
  • Ex ia input protection for Zone 0/1/2 hazardous areas
  • ATEX, IECEx, and FM approvals for global compliance
  • Reinforced galvanic isolation (300 Veff) for signal integrity
Universal Frequency Converter
  • Wide input frequency range from 0.001 Hz to 5 kHz
  • High accuracy of 0.1% of measured value
  • Fast response with measuring time < 100 ms
Four Versatile Outputs
  • 2 relay outputs (Form C changeover) for trip alarm and switching
  • 1 electronic transistor output for additional control
  • 1 analog output (0/4-20 mA) for proportional signal transmission
Enhanced Diagnostics & Safety
  • Line Fault Detection for wire breakage and short-circuit monitoring
  • SIL 2 functional safety certification
  • LED status indicators according to NAMUR NE44
Applications
Industry Application Examples
Oil & Gas Flow monitoring from frequency-output sensors in hazardous areas
Chemical / Pharmaceutical Tank level monitoring, reactor speed feedback
Process Automation Frequency monitoring from flow meters, speed sensors
Factory Automation Conveyor speed monitoring, RPM measurement
Safety Systems SIL2-rated frequency monitoring for safety functions
Certifications & Compliance
Certification Standard Details
ATEX 2014/34/EU TÜV 99 ATEX 1471 -- II (1)G [Ex ia Ga] IIC
IECEx IEC 60079-0/11 IECEx TUN 04.0007 -- [Ex ia Ga] IIC
SIL 2 IEC/EN 61508 / IEC/EN 61511 Functional Safety
FM Hazardous Locations Control drawing 16-538FM-12
CE/UKCA EMC & Low Voltage Directives UK Conformity Assessed

Overall Rating

5.0
Based on 50 reviews for this supplier

Rating Snapshot

The following is the distribution of all ratings
5 stars
100%
4 stars
0%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

S
Soh
Singapore Dec 19.2019
The goods arrive very fast, so down time was shorten. Ms Michelle was very helpful in answering all my questions and concerns. She is also very efficient in getting back to me with all the answers I needed. Overall 5 STARS.
E
Ejiro
Nigeria Mar 6.2019
The vendor representative, Mitchell, is an awesome lady as she ensured that the order was delivered promptly to my location. Beyond that, she stood by me with all technical details to resolve issues I had on the machine. I couldn’t have had better services than this. Thank you Mitchell. Ejiro.
J
Juan
Ecuador Jan 17.2019
all is ok !!
Contact Details
Shenzhen Hengyo Power Technology Co., Limited

Contact Person: Vivian Chan

Tel: +86 13510341645

Send your inquiry directly to us (0 / 3000)