Home ProductsPhoenix Contact Power Supply

Phoenix Contact Quint Power Power Supply 2904601 QUINT4-PS/1AC/24DC/10

Certification
china Shenzhen Hengyo Power Technology Co., Limited certification
china Shenzhen Hengyo Power Technology Co., Limited certification
I'm Online Chat Now

Phoenix Contact Quint Power Power Supply 2904601 QUINT4-PS/1AC/24DC/10

Phoenix Contact Quint Power Power Supply 2904601 QUINT4-PS/1AC/24DC/10
Phoenix Contact Quint Power Power Supply 2904601 QUINT4-PS/1AC/24DC/10 Phoenix Contact Quint Power Power Supply 2904601 QUINT4-PS/1AC/24DC/10

Large Image :  Phoenix Contact Quint Power Power Supply 2904601 QUINT4-PS/1AC/24DC/10

Product Details:
Place of Origin: Thailand
Brand Name: Phoenix Contact
Model Number: QUINT4-PS/1AC/24DC/10
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: original package
Delivery Time: 3 working days
Payment Terms: T/T,Western Union
Supply Ability: 500pcs/month
Contact Now Chat Now

Phoenix Contact Quint Power Power Supply 2904601 QUINT4-PS/1AC/24DC/10

Description
Condition: Original Brand New Warranty: One Year
Shipping Way: DHL FedEx Express Application: Automation Industries, Oil, Gas, Chemical Industries
Certificate: CE ISO TUV
Highlight:

2904601 QUINT4-PS/1AC/24DC/10

,

Quint Power Power Supply 2904601

,

Phoenix Contact Quint Power Power Supply

Phoenix Contact UPS QUINT4-PS/1AC/24DC/10 Power Supply 2904601

Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (selective fuse breaking) technology, and NFC interface, input: 1-phase, output: 24 V DC/10 A

The fourth generation of the high-performance QUINT POWER power supplies ensures superior system availability by means of new functions. Signaling thresholds and characteristic curves can be individually adjusted via the NFC interface.
The unique SFB technology and preventive function monitoring of the QUINT POWER power supply increase the availability of your application.

Control input (configurable) Rem Output power ON/OFF (SLEEP MODE)
Default Output power ON (>40 kΩ/24 V DC/open bridge between Rem and SGnd)
AC operation
Network type Star network
Nominal input voltage range 100 V AC ... 240 V AC
Input voltage range 100 V AC ... 240 V AC -15 % ... +10 %
Derating < 100 V AC (1 %/V)
Electric strength, max. 300 V AC 60 s
Typical national grid voltage 120 V AC
230 V AC
Voltage type of supply voltage AC
Inrush current typ. 12 A (at 25 °C)
Inrush current integral (I2t) < 0.7 A2s
Inrush current limitation 12 A (after 1 ms)
AC frequency range 50 Hz ... 60 Hz -10 % ... +10 %
Frequency range (fN) 50 Hz ... 60 Hz -10 % ... +10 %
16.7 Hz (acc. to EN 50163)
Mains buffering time typ. 42 ms (120 V AC)
typ. 44 ms (230 V AC)
Current consumption 3.4 A (100 V AC)
2.8 A (120 V AC)
1.5 A (230 V AC)
1.5 A (240 V AC)
Nominal power consumption 274 VA
Protective circuit Transient surge protection; Varistor, gas-filled surge arrester
Power factor (cos phi) 0.94
Switch-on time < 1 s
Typical response time 300 ms (from SLEEP MODE)
Input fuse 8 A (slow-blow, internal)
Recommended breaker for input protection 10 A ... 16 A (Characteristic B, C, D, K or comparable)
Discharge current to PE < 3.5 mA
0.7 mA (264 V AC, 60 Hz)
DC operation
Nominal input voltage range 110 V DC ... 250 V DC
Input voltage range 110 V DC ... 250 V DC -18 % ... +40 %
Derating < 110 V DC (1 %/V)
Voltage type of supply voltage DC
Current consumption 3 A (110 V DC)
1.3 A (250 V DC)

Efficiency typ. 92.5 % (120 V AC)
typ. 93.4 % (230 V AC)
Output characteristic U/I Advanced
Smart HICCUP
FUSE MODE
Nominal output voltage 24 V DC
Setting range of the output voltage (USet) 24 V DC ... 29.5 V DC (constant capacity)
Nominal output current (IN) 10 A
Static Boost (IStat.Boost) 12.5 A
Dynamic Boost (IDyn.Boost) 20 A (5 s)
Selective Fuse Breaking (ISFB) 60 A (15 ms)
Magnetic circuit breaker tripping A1...A6 / B2...B6 / C1...C3 / Z1...Z6
Derating > 60 °C ... 70 °C (2.5 %/K)
Feedback voltage resistance ≤ 35 V DC
Protection against overvoltage at the output (OVP) ≤ 32 V DC
Control deviation < 0.5 % (Static load change 10 % ... 90 %)
< 4 % (Dynamic load change 10 % ... 90 %, (10 Hz))
< 0.25 % (change in input voltage ±10 %)
Residual ripple < 80 mVPP (with nominal values)
Short-circuit-proof yes
No-load proof yes
Output power 240 W
300 W
480 W
Apparent power 336 VA (120 V, UOUT = 24 V, IOUT = stat. Boost)
345 VA (230 V, UOUT = 24 V, IOUT = stat. Boost)
Maximum no-load power dissipation < 3 W (120 V AC)
< 3 W (230 V AC)
Power loss nominal load max. < 20 W (120 V AC)
< 17 W (230 V AC)
Power dissipation SLEEP MODE < 3 W (120 V AC)
< 3 W (230 V AC)
Crest factor typ. 1.50 (120 V AC)
typ. 1.67 (230 V AC)
Rise time < 1 s (UOut = 10 % ... 90 %)
Connection in parallel yes, for redundancy and increased capacity
Connection in series yes
Fuse protection (secondary side) electronic
thermal-magnetic
thermal
Signal
Signal ground SGnd Reference potential for Out1, Out2, and Rem
Signal Out 1 (configurable)
Digital 24 V DC 20 mA
Default 24 V DC 20 mA 24 V DC for UOut > 0.9 x USet
Signal Out 2 (configurable)
Analog 4 mA ... 20 mA ±5 % (Load ≤400 Ω)
Default 24 V DC 20 mA 24 V DC for POut < PN
Signal relay 13/14 (configurable)
Default closed (Uout > 0.9 USet)
Digital 24 V DC 1 A
30 V AC/DC 0.5 A

Input
Connection method Screw connection
Conductor cross-section, rigid min. 0.2 mm²
Conductor cross-section, rigid max. 2.5 mm²
Conductor cross-section flexible min. 0.2 mm²
Conductor cross-section flexible max. 2.5 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min. 0.25 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max. 2.5 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min. 0.25 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max. 2.5 mm²
Conductor cross-section AWG min. 24
Conductor cross-section AWG max. 14
Stripping length 6.5 mm
Tightening torque, min 0.5 Nm
Tightening torque max 0.6 Nm
Output
Connection method Screw connection
Conductor cross-section, rigid min. 0.2 mm²
Conductor cross-section, rigid max. 2.5 mm²
Conductor cross-section flexible min. 0.2 mm²
Conductor cross-section flexible max. 2.5 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min. 0.25 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max. 2.5 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min. 0.25 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max. 2.5 mm²
Conductor cross-section AWG min. 24
Conductor cross-section AWG max. 14
Stripping length 6.5 mm
Tightening torque, min 0.5 Nm
Tightening torque max 0.6 Nm
Signal
Connection method Push-in connection
Conductor cross-section, rigid min. 0.2 mm²
Conductor cross-section, rigid max. 1 mm²
Conductor cross-section flexible min. 0.2 mm²
Conductor cross-section flexible max. 1.5 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min. 0.2 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max. 0.75 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min. 0.2 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max. 1.5 mm²
Conductor cross-section AWG min. 24
Conductor cross-section AWG max. 16
Stripping length 8 mm